LT MOTORS >> 350-1500 KW
Product Category

Range
Supply Voltage : upto 690V
 
Output : 300 to 1500kW
IEC Frame Size : 355 to 560
Supply Frequency : 50 Hz and 60 Hz
Number of Poles : 2 Pole to 20 Pole
Type : Squirrel Cage (SCR), Slip Ring (SR)
Enclosure :TEFC, CACA, TETV, CACW, SPDP
Cooling :IC4A1A1, IC6A1A1,IC5A1A1, IC8A1W7, IC01A1
Degree of Protection : IP55, IP23
Mounting : Horizontal foot mounted
: Vertical Flanged Mounted
Special Execution
(in squirrel cage)
a) Nonsparking type IS 9628
b) Increased safety type to IS 6381
c) Motors for Solid State Control (VVVF)
Standards
: Specification IEC34 - 1, IS 325, IS 4722
: Dimensions IEC 72-A, IS 8223, IS 2223
: Degree of protection IEC34 - 5, IS 4691
: Cooling IEC34 - 6, IS 6362
: Construction & mounting IEC34 - 7, IS 2253
: Noise level IEC34 - 9, IS 12065
: Vibration IEC34 - 14, IS 12075
: Testing IEC34 - 1, JEC37, IS 325
Applications
Pumps, Compressors, Fans, Blowers, Mills, Crushers, Haulages, Conveyors, Agitators, Ring Granulators, Rubber Mills, Rubber Mixers, Disc Refiners, Rerolling Mill etc.




Method of cooling
: IC4A1A1 - TEFC Totally Enclosed FanCooled(Surface Cooled)
Major Features

:Energy efficient surface cooled motors

:Robust Steel Frame
: Solid Deep Rotor Bars in Single Cage
: Special Double Cage as per Drive
: Endshield Mounted Bearings
: Antifriction Bearings
: Dynamically Balanced Rotors
: Stringent Quality Checks
: Highly reliable Class 'F' Insulation with Class 'B' temp. rise
: High efficiency
: Low noise levels
: Low vibration levels
: Ease of Maintenance
: Space Heaters
Other Features : Phase Segregated Terminal  Box (Fault withstanding type) for HT only
: Winding Temp. Detectors (RTD)  for HT , PTC thermisters for LT.
: Bearing Temp. Detectors (RTD)
: Bearing Temp. Indicators (Dial Type)
: Mounting of Vibration Probes


Method of cooling : IC6A1A1 - Closed Air Circuit Air Cooled
Major Features : Unit Construction
: Robust Steel Frame
: Spider type Shaft
: Double Ended Radial Ventilation
: Solid Deep Rotor Bars in Single Cage
: Special Double Cage as per Drive
: Endshield Mounted Bearings
: Antifriction/Sleeve Bearings
: Dynamically Balanced Rotors
: Stringent Quality Checks
: Highly reliable Class 'F' Insulation with Class 'B' temp. rise
: Ease of Maintenance
: Space Heaters
: On line greasing for bearings
Other Features : Winding Temp. Detectors (RTD)  for HT , PTC thermisters for LT.
: Bearing Temp. Detectors (RTD)
: Bearing Temp. Indicators (Dial Type)
: Mounting of Vibration Probes
: Phase Segregated Terminal Box (Fault withstanding type) for HT
: Star Point Terminal Box
: Air temperature Indicators (Dial Type)

 

Method of cooling :IC5A1A1-Totally Enclosed Tube  Ventilated
Major Features :Robust Steel Frame

:Spider type Shaft
:Double Ended Radial Ventilation
:Solid Deep Rotor Bars in single Cage
:Special Double Cage as per Drive
:Endshield Mounted Bearings
:Antifriction/Sleeve Bearings
:Dynamically Balanced Rotors
:Stringent Quality Checks
:Highly reliable Class 'F' Insulation with Class 'B' temp. rise
:Ease of Maintenance
:Space Heaters
Other Features : Winding Temp. Detectors (RTD)
: Bearing Temp. Detectors (RTD)
: Bearing Temp. Indicators (Dial Type)
: Mounting of Vibration Probes
: Phase Segregated Terminal Box (Fault withstanding type)
: Star Point Terminal Box
Applications
Pumps, Compressors, Fans, Blowers, Haulages, Conveyors, etc

 

Method of cooling : IC8A1W7 - CACW Closed Air Circuit Water Cooled
Major Features : Unit Construction
: Robust Steel Frame
: Spider type Shaft
: Double Ended Radial Ventilation
: Solid Deep Rotor Bars in Single  Cage
: Special Double Cage as per Drive
: Endshield Mounted Bearings
: Antifriction/Sleeve Bearings
: Dynamically Balanced Rotors
: Stringent Quality Checks
: Highly reliable Class 'F' Insulation with Class 'B' temp. rise
: Ease of Maintenance
: Space Heaters
: On line greasing for bearings
Other Features : Winding Temp. Detectors (RTD)  for HT, PTC thermisters for LT
: Bearing Temp. Detectors (RTD)
: Bearing Temp. Indicators (Dial Type)
: Mounting of Vibration Probes
: Phase Segregated Terminal Box (Fault withstanding type) for HT
: Star Point Terminal Box
: Water Leakage Detector
: Water Flow Switches

 

Method of cooling : IC01A1 - Screen Protected Drip Proof
Major Features :Robust Steel Frame
:Spider type Shaft
:Double Ended Radial Ventilation
:Solid Deep Rotor Bars in Single Cage
:Special Double Cage as per Drive
:Endshield Mounted Bearings
:Antifriction/Sleeve Bearings
:Dynamically Balanced Rotors
:Stringent Quality Checks
:Highly reliable Class 'F' Insulation with Class 'B' temp. rise
:Ease of Maintenance
:Space Heaters
Other Features :Winding Temp. Detectors (RTD)  for HT, PTC thermisters for LT





: Bearing Temp. Detectors (RTD)
: Bearing Temp. Indicators (Dial Type)
: Mounting of Vibration Probes
: Phase Segregated Terminal Box (Fault withstanding type) for HT
: Star Point Terminal Box